devention DEVO 7E User Manual page 62

7-channel micro computer system
Table of Contents

Advertisement

Welcome to use the DEVO 7E transmitter
cleUention
DEVO 7E
Point-Right Setting: Press UP or DN to choose "Point-Right". Press R or L to inhibit or active. If need to adjust
please active it. There will be expanded value adjustment item. Press UP or DN to choose "0%" If need to
adjust the value, press L (0% means no adjusting). A minus value means the amending direction is downward;
press R to adjust value (0% means no adjusting). A plus value means the amending direction is upward.
The adjustable range is 100%.
Balance
Balance
Point - Hight
Point -
Inhibit
oc) , : ;
Press UP or DN, there will be setting for Point-1, Point-2, Point-3, Point-Left, Point>Left, refer to the setting
method as above. Press EXT after finished it.
3.9 Gyro sensor
This function offers the gain adjustment for gyro sensor, which can be manually set through HOLD switches
or Flight mode switch, and also is possible to be automatically switched among various gains through flight
mode switch. (The flight mode should be activated. Refer to "2.9 Device Select").
Setup:
Press ENT to enter Main menu; Press UP or DN to choose
Function menu. Press ENT to enter Function menu; Press
UP or DN to choose Gyro sensor, then press ENT to Gyro
Sensor interface.
(1) Manual Setting
Gyro
SPM=;or
I Ii B
Manual
h a.n A
PI
U
1E1
(1.1) Manual Setup: In the Gyro Sensor interface, here are Manual set and Automatic set for selectable choice.
Press R or L to select Manual option. ( Automatic setting can be activated if Flight mode is act, refer to "2.9
Device selection" ) . Choose "Manual Setup"
(1.2) Channel: The factory default channel is AUX 2. the Output set offer the function to change other control
channels (refer to "2.10 Output").
(1.3) Switch Select: In the interface of Gyro Sensor, press UP or DN to choose SWITCH, there are FMODSW
and HOLDSW for selectable sets, press R or L to choose the desired switch for Manual control.
(1.4) Sensitivity Setup: If the switch selection is two level, there are Position 0 and Position 1 two selection
which can set the sensitivity individually.
(1.4.1) Status:turn the setting gyro control switch, the status
G
s1.0
e:;or
items will display the current switch status position.
I
(1.4.2) Pos 0:Press UP or DN to move the navigational mark
C:
to Pos 0 and press R or L to increase or decrease, respectively,
H 0 LD Vy°
the value.If the gyro used has two modes of NOR and AVCS,
3 t at
S
NOR will be activated when the value is less than 50.0%.
In NOR mode, the smaller the value is, the bigger the gyro
sensor gain will be. The factory setting is 50.0%.
(1.4.3) "Pos 1" is the same setting way as above "Pos 0".
(2) Automatic setting
(2.1) Automatic Setup: in the Gyro Sensor interface,press
UP or DN to choose Mode, there are Manual set and
Automatic set for selectable choice. Press R or L to select
Automatic option.
(2.2) Channel: The factory default channel is AUX2, the
Output set offer the function to change other control channels
(Refer to "2.10 Output").
Gyro Sensor
Mode
Automatic
1
II
Channel
u:0 _I
(2.3) Switch:The switch function isn't available under Automatic setting.
DEVO 7E - 59

Advertisement

Table of Contents
loading

Table of Contents