4.9.3.1. How to validate the total pulse output

Description
 Validates the total pulse output for DO1 OUT and/or DO2 OUT.
 + TOTAL PULSE : Outputs flow rate total pulse in forward direction.
- TOTAL PULSE : Reverse flow rate total pulse output.
Note) Referring to Section 4.9.2.1., set the pulse value, pulse width, etc.
For concrete keying, refer to the typical operation indicated below. Set the protection to OFF beforehand. (See Section 4.4.1.)
Operation
Set the DO1 output to "+ TOTAL PULSE".
(example)
Also, set the contact to "ACTIVE ON".
Key operation
Press the
Press the
ENT
Press the
* Press the
Press the
ENT
Press the
Press the
Press the
ENT
――― "+TOTAL PULSE" has been registered. ―――
Press the
ENT
Press the
ENT
* To select normally on, press the
Press the
ESC
the measurement mode.
- 40 -
Description
key twice to display "OUTPUT SETUP".
key once to display "ZERO ADJUSTMENT".
ENT
key for 6 times to display "DO1 OUT".
key again to display "DO2 OUT".
key once to blink the cursor.
ENT
key once to display "+ TOTAL PULSE " on the 2nd line.
key again to select "- TOTAL PULSE".
key once to register "+TOTAL PULSE".
ENT
key once to display "CONTACT ACTION".
ENT
key once to register "ACTIVE ON" (normally off).
ENT
key.
――― "ACTIVE ON" has been registered. ―――
key twice and then press the
ESC
OUTPUT SETUP
ZERO ADJUSTMENT
DO1 OUT
DO1 OUT
DO1 OUT
DO1 OUT
STATUS OUT
CONTACT ACTION
CONTACT ACTION
STATUS OUT
key for 3 times to enter
Display
SET ZERO
NOT USED
NOT USED
+TOTAL PULSE
 COMPLETE 
CONTACT ACTION
ACTIVE ON
 COMPLETE 
CONTACT ACTION
0.000
m3/h
0.000
m3
INF-TN3FLR-E