How To Set The Flow Rate Unit - Fuji Electric FLR-3 Instruction Manual

Ultrasonic flowmeter m-flow pw flow transmitter
Table of Contents

Advertisement

4.8.2. How to set the flow rate unit

Description
 Select the unit of flow rate.
 Metric system
Flow rate ······· L/s, L/min, L/h, L/d, kL/d, ML/d, m
kBBL/d, MBBL/d
<Note> First, set the unit system (metric) according to Section 4.8.1.
For actual keying, refer to the typical operation indicated below. Set the protection to OFF beforehand. (See Section 4.4.1.)
Operation
Set a flow rate unit to "L/min".
(example)
Key operation
Press the
Press the
ENT
Press the
Press the
ENT
Press the
Press the
ENT
ESC
Press the
measurement mode.
- 28 -
3
3
/s, m
Description
key for 3 times to display "MEASURE SETUP".
key once to display "SYSTEM UNIT".
ENT
key once to display "FLOW UNIT".
key once to blink the cursor.
ENT
key several times to display "L/min".
key once to register.
ENT
――― "L/min" has been registered. ―――
ESC
key once and the
key twice to return to the
3
3
/min, m
/h (factory set), m
/d, km
3
3
/d, Mm
/d, BBL/s, BBL/min, BBL/h, BBL/d,
Display
MEASURE SETUP
SYSTEM UNIT
FLOW UNIT
FLOW UNIT
FLOW UNIT
FLOW UNIT
 COMPLETE 
FLOW UNIT
0.000
m/s
0.000
L/min
INF-TN3FLR-E
METRIC
m3/h
m3/h
L/min
L/min

Advertisement

Table of Contents
loading

Table of Contents