How To Connect To Terminal Block; Cable Treatment; How To Connect To Power Supply/Terminal Block For Signal - Fuji Electric FLR-3 Instruction Manual

Ultrasonic flowmeter m-flow pw flow transmitter
Table of Contents

Advertisement

3.3.5. How to connect to terminal block.

3.3.5.1. Cable treatment

The cable connecting to the terminal block is available to connect with bare wire but for safety's sake please crimp the bar
terminal to connect.
When you cut and use the signal cable, make sure to cut the cable in same length of upstream and downstream.
Note) if cable lengths are different, it may adversely affect the output.
Usable wiring materials
• Wire
2
Gauge: AWG20 (0.5mm
) to AWG16 (1.5mm
Strip-off length: 8 to 10mm
AWG20
to
AWG16
8 to 10mm
2
Wire size (mm
)
0.5
0.75
1
1.5
Note1) Make sure to use PZ6/5(H0.25 to H6 for sleeve) as a crimp tool for caulking.
Note2) Applicable sleeve is required for electric wire.
Note3) Insert the electric wire to the end of H sleeve so as to crimp.
Note4) Length of stripped wire is 12mm.

3.3.5.2. How to connect to power supply/terminal block for signal.

Please prepare the flathead screwdriver (head size: 0.6 x 3.5mm) so as to tighten the cable.
1. Pull off the cable socket side from the plug on the substrate with holding the right side of the socket by hand.
2. If cable connector is closed, turn the screw to the left on the top to open.
3. Insert the cable and turn the screw to the right on the top to fix.
4. Install the cable socket side to the plug on the substrate.
Note) Make sure to conduct the procedure not to damage the printed-circuit board when you remove and install the cable
socket side.
- 10 -
2
)
AWG
øD1 (mm)
20
1
18
1.2
17
1.4
16
1.7
Cable socket side
Plug on substrate
• Bar terminal
Weidmuller
www.weidmuller.com
10
øD1
øD2 (mm)
2.6
H0.5/16
2.8
H0.75/16
3
H1/16
3.5
H1.5/16
øD2
16
Type
INF-TN3FLR-E