Factory-set value is shown below. (When parameter setting is not provided.)
Setting unit
1
Parameter protection
2
ID No
3
Language
4
System unit
5
Flow unit
6
Total unit
7
Outer diameter
8
Pipe material
9
Wall thickness
10
Lining material
11
Lining thickness
12
Kind of fluid
13
Dynamic viscosity
coefficient
14
Sensor mounting method
15
Sensor type
16
Zero adjustment
17
Damping
18
Low flow cut
19
Content of display 1st
line
20
Decimal point position
of display 1st line
21
Content of display 2nd
line
22
Decimal point position
of display 2nd line
23
Kind
24
Range type
25
Full scale 1
26
Full scale 2
27
Hysteresis
28
Burnout (current)
29
Burnout timer
30
Output limit low
31
Output limit high
32
Rate limit
33
Rate limit timer
34
Total mode
35
Total rate
36
Total preset
37
Pulse width
38
Burnout (total)
39
Burnout timer
- 18 -

4.3. Parameter initial value list

Setting range
No. of menu: 2
0000 to 9999
No. of menu: 5
No. of menu: 2
No. of menu:18
No. of menu: 8
6.00 to 1400.00mm
No. of menu: 13
Sound velocity: 1000 to
3700m/s
0.10 to 100.00mm
No. of menu: 8
Sound velocity: 1000 to
3700m/s
0.01 to 100.00mm
No. of menu: 18
Sound velocity: 300 to
2500m/s
0.001 to 999.999
-6
2
×10
m
/s
No. of menu: 2
No. of menu: 4
No. of menu: 2
0.0 to 100.0sec
0 to 5m/s in terms of
flow velocity
No. of menu: 7
No. of menu: 7
No. of menu: 2
No. of menu: 4
0, ±0.3 to ±10m/s in
terms of flow velocity
0, ±0.3 to ±10m/s in
terms of flow velocity
0.00 to 20.00
No. of menu: 5
10 to 900sec
-20 to 0%
100 to 120%
0 to 5m/s in terms of
flow velocity
0 to 900sec
No. of menu: 3
0.000000 to 99999999
0.000000 to 99999999
No. of menu: 7
No. of menu: 2
10 to 900sec
Initial value
PROTECTION ON
PROTECTION ON, PROTECTION OFF
0000
ID No. is invalid when 0000 is selected.
English *1
English, Japanese, German, French and
Spanish
Metric
Metric or inch
3
m
/h
L/s, L/min, L/h, L/d, kL/d, ML/d, m
3
3
m
/h, m
BBL/h, BBL/d, kBBL/d, MBBL/d
3
m
mL, L, m
60.00mm
[mm, in]
PVC
Carbon steel, stainless, PVC, Copper,Cast
iron, Aluminum, FRP, Ductile iron, PEEK,
PVDF, Acrylic and PP
Pipe sound velocity
(Sound velocity: [m/s, ft/s])
4.00mm
[mm, in]
No lining
No lining, Tar epoxy, Mortar, Rubber, Teflon,
Pyrex glass, PVC
Lining S.V. (Sound velocity: [m/s, ft/s])
[mm, in]
Water
Seawater, dist. water, ammonia, alcohol,
benzene, bromide, ethanol, glycol, kerosene,
milk, methanol, toluol, lube oil, fuel oil, petrol
and refrigerant R410
Fluid S.V. (Sound velocity:
-6
2
1.0038
[×10
m
-6
2
×10
m
/s
V method
V method, Z method
FSSA/FSSG
FSSA/FSSG, FLS_12/FLS_22,FSSC,
FLS_31/FLS_41
Clear (unadjusted)
Clear, adjustment (Clear has been factory-set.)
5.0sec
sec
3
0.150m
/h
[(5) unit]
Flow velocity (m/s)
Flow velocity, Flow rate, Flow rate (%), +Total
(Actual), +Total pulse, -Total (Actual) and -Total
pulse
 . 

(Fill in the specified digit)
Flow rate (m/s)
Flow velocity, Flow rate, Flow rate (%), +Total
(Actual), +Total pulse, -Total (Actual) and -Total
pulse
 . 

(Fill in the specified digit)
Flow rate
Flow velocity, Flow rate
Single range
Single range, Auto 2 range, Bi-dir range and
Bi-dir Auto 2 range
3
15.000m
/h
[(5) unit]
3
0.000m
/h
[(5) unit]
10.00%
%
Hold
Not used, Hold, Lower, Upper and Zero
10sec
sec
-20%
%
120%
%
3
0.000m
/h
[(5) unit]
0sec
sec
Stop
Start, Stop and Reset
3
0m
[(6) unit]
3
0m
[(6) unit]
50.0msec
5.0msec, 10.0msec, 50.0msec, 100.0msec,
200.0msec, 500.0msec,1000msec.
Hold
Not used, hold
10sec
sec
Setting value
3
/s, m
3
3
/d, km
/d, Mm
/d, BBL/s, BBL/min,
3
3
3
, km
, Mm
, mBBL, BBL, kBBL
[m/s, ft/s])
2
/s, ft
/s]
INF-TN3FLR-E
3
/min,