6.4.2.

Installation of External SATA Devices

The following information pertains to external SATA devices which may be connected to the CP6007 via normal
cabling.
Some symptoms of incorrectly installed SATA devices are:
Device on a SATA channel does not spin up: check power cables and cabling. May also result from a bad power
supply or SATA device.
The SATA connector on the CP6007 provides only a data connection. The power for this device must be supplied
by a separate connector. For further information, refer to the respective documentation of the device.
SATA device fail message at boot-up: may be a bad cable or lack of power going to the drive.
6.4.3.

PMC Module Installation

The CP6007 supports the installation of a PMC module via the J21 to J22 connectors. For information on the
installation of the PMC module, refer to the documentation provided with the module.

Figure 15: CP6007-SA with PMC/XMC Module installed (marked red)

6.4.4.

XMC Module Installation

The CP6007 supports the installation of an XMC module via the J20 connector. For information on the installation of
the XMC module, refer to the documentation provided with the module.
6.4.5.

Rear Transition Module Installation

For physical installation of rear transition modules, refer to the documentation provided with the module itself.

6.5. Battery Replacement

The CP6007 RTC may be backed up using a single UL-approved CR2025, 3.0 V "coin cell" lithium battery from one of
two possible points of installation:
onboard
on the rear transition module
Only one battery may be installed at a time. Refer to Table 1 for battery requirements.