8.8. OEM Event/Reading Types

OEM (Kontron) specific sensor types and codes are presented in the following table.

Table 60: OEM Event/Reading Types

OEM SENSOR
TYPE (CODE)
Firmware Info 1 (C0h)
Firmware Info 2 (C0h)
Initialization Agent (C2h)
FRU Agent (C5h)
Post Value (C6h)
Firmware Upgrade Manager (C7h)
Board Reset (CFh)
www.kontron.com
OEM EVENT/
READING TYPE (CODE)
70h
71h
03h
("digital" Discrete)
0Ah
(Discrete)
6Fh
(sensor type specific)
6Fh
(sensor type specific)
03h
("digital" Discrete)
CP6007-SA, CP6007-RA – User Guide, Rev. 1.0
DESCRIPTION
Internal Diagnostic Data
Internal Diagnostic Data
Offsets / events:
0: Initialization O.K.
1: Initialization Error
FRU initialization agent, using a standard
reading type.
Error is detected if the POST code is != 0 and
doesn't change for a defined amount of time.
In case of no error:
Bits [7:0] = POST code (payload Port 80h)
In case of error:
Bits [15:0] = 4000h
Data2 = POST code, low nibble
Data3 = POST code, high nibble
Offsets / events:
0: First Boot after upgrade
1: First Boot after rollback (error)
2: First Boot after errors (watchdog)
3: First Boot after manual rollback
4..7: Reserved
8: Firmware Watchdog Bite, reset occurred
Data 2 contains the reset type:
...WARM = 0
...COLD = 1
...FORCED_COLD = 2
...SOFT_RESET = 3
...MAX = 4
Data 3 contains the reset source:
...IPMI_WATCHDOG = 0
...IPMI_COMMAND = 1
...PROC_INT_CHECKSTOP = 2
...PROC_INT_RST = 3
...RESET_BUTTON = 4
...POWER_UP = 5
...LEG_INITIAL_WATCHDOG = 6
...LEG_PROG_WATCHDOG = 7
...SOFTWARE_INITIATED = 8
...SETUP_RESET = 9
...UNKNOWN = 0xFF