Table 5-30 - Viavi CX100 ComXpert Operation Manual

Handheld radio test set
Hide thumbs Also See for CX100 ComXpert:
Table of Contents

Advertisement

Chapter 5 RF Instrument Function Descriptions
VSWR/DTF
5.4.3.3
VSWR Display Settings
The Display Settings soft-key opens a menu that contains controls and settings that
affect display layout and manages how traces are displayed on plot fields.
Control/Setting
Rotate Screen
Active Trace
Button
Average (Field)
Capture Trace
Button
Clear Trace
Button
Rev 002
5 - 62
Table 5-30 VSWR Display Settings
Description
The Rotate Screen soft-key switches the UI between Portrait
or Landscape orientation.
Changes orientation of plot field on the device (updates remote
session when using VNC application to view the UI).
Orientation is not stored as part of Save Trace settings.
The Active Trace button opens a window that selects the type
of trace(s) to be displayed on the plot field. Multiple traces can
be selected at any given time on each plot.
Max: displays highest signal received
Min: displays lowest signal received
Live: displays live signal trace
Average: displays an averaged signal trace; average is
defined by the value in the Average field.
The Average field is enabled when Average is selected as the
active trace. The Average field defines the number of traces to
be used to calculate an average signal trace.
When the Capture Trace button is pressed, a trace is "held"
on the display. When more than one trace is active on a plot,
only one of the active traces will be captured. When multiple
trace types are enabled, traces are captured in the following
priority:
MAX Priority 1
MIN Priority 2
Average Priority 3
Live Priority 4
For example, if Average and Live traces are enabled, the
Average Trace is captured. If Max and Average traces are
enabled, the Max trace is captured.
When the Capture Trace button is pressed, the Clear Trace
button is enabled which is used to remove a captured trace
from the plot field.
The Clear Trace button is active when a the Captured Trace
button has been pressed and a trace is captured on the plot
field. Pressing the Clear Trace button removes the captured
trace from the plot field.
CX100 ComXpert Operation Manual
22144015
August 2023