CT-4 and CT-X Quick Verify Determine Estimated CT-4 and CT-X Levels This procedure is not to be used to set or adjust the CT-4/CT-X levels but to verify if the measured level is within the appropriate limits and determine the CT-4/CT-X needs to be adjusted.
Page 2
Proper Levels, no action required •Ch 88 or 89 power level -24 dBc to -25 dBc = acceptable level •Ch 16 or 17 power level -24 dBc to -25 dBc = acceptable level If any of the above is not true, schedule headend visit Connect signal to port 1 of the ONX CATV Home Screen select...
Page 3
ONX builds channel plan and provides measurement for all channels in the plan Figure 2: Channel Check Start Note the Power Level of the selected Channels...
Measured Results (612 MHz) (138Mhz) Note: These are approximate levels to verify leakage levels are within the expected limits. If levels are off by 3 dB too low, then leakage readings will be cut by ½. Example: A 20 microvolt leak would by only 10 microvolts.