Inertial Measurement Unit IMUF99*B16

Installation

3
Installation
3.1

Electrical connection

The IMUF99PL-* is equipped with 2 connectors M12 x 1, 5-pin, male and female for CAN bus
integration. If a terminator is required, it must be attached externally on the female connector.
Therefore e. g. "Terminator ICZ-TR-CAN/DN-V15" from Pepperl+Fuchs is available (also see
datasheet of the sensor).
Pin
1
2
3
4
5
Table 3.1
Note
The wire colors listed above apply when one of the bus cables from the Pepperl+Fuchs
accessories range is used.
Note
The device complies with the EMC norms and standards described in the datasheets. If
necessary, additional external EMC protection elements and interference suppression
measures (e.g. filters) are recommended.
Warning!
Damage to the device
Connecting an alternating current or excessive supply voltage can damage the device or cause
the device to malfunction.
Electrical connections with reversed polarity can damage the device or cause the device to
malfunction.
Connect the sensor to direct current (DC). Ensure that the supply voltage rating is within the
specified sensor range. Ensure that the connecting wires on the cordset in use are connected
correctly.
Connecting the sensor to the voltage
1.
Connect the operating voltage to pins 2 and 3 of the 5-pin connector.
The "Power" LED lights up yellow.
14
1
n.c.
2
+U B
3
GND
4
CAN-H
5
CAN-L
Wire color
Brown
White
Blue
Black
Gray
Connector assignment
Designation
Not used
+UB
GND
CAN-H
CAN-L