Installation

5
Installation
5.1

Note on Safety

Warning!
Risk of short circuit
Working on live parts can cause injuries and can compromise the function and the electrical
safety of the device.
Before working on the device, always disconnect the supply voltage.
Connect the device to the supply voltage only after completion of the work.
5.2

Mounting

Mount the sensor as follows:
Mounting
1. Place the sensor on a stable mounting bracket or another suitable base.
2. Align the sensor so that the axis of rotation to be detected is centered on the housing bore
hole.
3. Fix the sensor by means of two cylinder head bolts M5 (thread length ≥ 20 mm).
4. Check for rigid and stable seating of the sensor.
5. Mount the actuator or a self-made actuation element on the rotation shaft (if not already
mounted) .
6. Check for the required actuator dimensions and gap distance between sensor and actuator.
The actuator must not make physical contact or scratch the sensors surface when moving.
Using a different actuating element
You may use a different actuator instead of the BT-F130-A actuator provided. When using a
different actuating element, the element must fulfill all requirements relating to the material,
dimensions and distance to the sensitive surface on the sensors (see table). Failing to fulfill all
of these requirements may reduce the accuracy/resolution of the sensor or even cause the
sensor to stop functioning.