ABB ACS880 Firmware Manual page 72

Diode supply control program
Hide thumbs Also See for ACS880:
Table of Contents

Advertisement

72 Parameters
No.
Name/Value
114.28
AI1 force data
-22.000 ... 22.000
mA or V
114.29
AI1 HW switch pos
V
mA
114.30
AI1 unit selection
V
mA
114.31
RO status
0000h...FFFFh
114.31
AI1 filter gain
No filtering
125 us
250 us
500 us
1 ms
2 ms
4 ms
7.9375 ms
Description
(Visible when
114.01 Module 1 type
Forced value that can be used instead of the true
reading of the input. See parameter
Forced value of analog input AI1.
(Visible when
114.01 Module 1 type
Shows the position of the hardware current/voltage
selector on the I/O extension module.
Note: The setting of the current/voltage selector must
match the unit selection made in parameter
unit
selection.
Volts.
Milliamperes.
(Visible when
114.01 Module 1 type
Selects the unit for readings and settings related to
analog input AI1.
Note: This setting must match the corresponding
hardware setting on the I/O extension module (see the
manual of the I/O extension module). The hardware
setting is shown by parameter
Volts.
Milliamperes.
(Visible when
114.01 Module 1 type
Status of relay outputs on the I/O extension module.
Example: 00000001b = RO1 is energized, RO2 is de-
energized.
Status of relay outputs.
(Visible when
114.01 Module 1 type
Selects a hardware filtering time for AI1.
See also parameter
114.32 AI1 filter
No filtering.
125 microseconds.
250 microseconds.
500 microseconds.
1 millisecond.
2 milliseconds.
4 milliseconds.
7.9375 milliseconds.
=
FIO-11
or FAIO-01)
114.22 AI force
sel.
=
FIO-11
or FAIO-01)
114.30 AI1
=
FIO-11
or FAIO-01)
114.29 AI1 HW switch
pos.
=
FIO-01
or FDIO-01)
=
FIO-11
or FAIO-01)
time.
Def/FbEq16
-
1000 = 1 mA
or V
-
2
10
mA
2
10
-
1 = 1
No filtering
0
1
2
3
4
5
6
7