116 Parameters
No.
Name/Value
No action
Fault
Fault always
Warning
150.33
FBA B comm loss
timeout
0.3 ... 6553.5 s
150.37
FBA B actual 1 type
150.38
FBA B actual 2 type
150.39
FBA B SW
transparent source
Not selected
Other [bit]
150.40
FBA B act1
transparent source
Not selected
Other [bit]
150.41
FBA B act2
transparent source
Not selected
Other [bit]
150.42
FBA B debug mode
Disable
Fast
Description
Communication break detection disabled.
Communication break detection active. Upon a
communication break, the diode supply unit trips on a
communication fault.
The supply unit trips on a communication fault even
though no control is expected from the fieldbus.
The supply unit generates a communication warning
even though no control is expected from the fieldbus.
Defines the time delay before the action defined by
parameter
150.32 FBA B comm loss func
count starts when the communication link fails to
update the message.
Time delay.
Selects the type and scaling of actual value 1
transmitted to the fieldbus network through fieldbus
adapter B.
For the selections, see parameter
type.
Selects the type and scaling of actual value 2
transmitted to the fieldbus network through fieldbus
adapter B.
For the selections, see parameter
type.
Selects the source of the fieldbus status word when
parameter 150.36 FBA B SW sel is set to Transparent
mode.
No source selected.
Source selection (see
Terms and abbreviations
39).
When parameter
150.37 FBA B actual 1 type
Transparent, this parameter selects the source of actual
value 1 transmitted to the fieldbus network through
fieldbus adapter B.
No source selected.
Source selection (see
Terms and abbreviations
39).
When parameter
150.38 FBA B actual 2 type
Transparent, this parameter selects the source of actual
value 2 transmitted to the fieldbus network through
fieldbus adapter B.
No source selected.
Source selection (see
Terms and abbreviations
39).
Enables the display of raw (unmodified) data received
from and sent to fieldbus adapter B in parameters
150.43...150.48.
Note that the changes made take effect only after
reboot or setting the parameter
refresh
to Refresh.
This functionality should only be used for debugging.
Display of raw data from fieldbus adapter B disabled.
Debug mode is enabled. Cyclical data update is as fast
as possible which increases the CPU load on the supply
unit.
is taken. Time
150.07 FBA A actual 1
150.07 FBA A actual 1
on page
is set to
on page
is set to
on page
154.27 FBA B par
Def/FbEq16
0
1
4
5
0.3 s
10 = 1 s
Transparent
Transparent
Not selected
-
-
Not selected
-
-
Not selected
-
-
Disable
0