ABB ACS880 Firmware Manual page 137

Diode supply control program
Hide thumbs Also See for ACS880:
Table of Contents

Advertisement

No.
Name/Value
196.63
User data logger
trigger
Off
On
Other
196.64
User data logger
start
Off
On
Other
196.65
Factory data
logger time level
500us
2ms
10ms
196.70
Disable adaptive
program
No
Yes
196.100
Change user pass
code
10000000...
99999999
196.101
Confirm user pass
code
10000000...
99999999
Description
Triggers, or selects a source that triggers, the user data
logger.
0.
1.
Source selection (see
Terms and abbreviations
39).
Starts, or selects a source that starts, the user data
logger.
0.
1.
Source selection (see
Terms and abbreviations
39).
Selects the sampling interval for the factory data logger
(see page 164).
500 microseconds.
2 milliseconds.
10 milliseconds.
Enables/disables the adaptive program (if present).
See also section
Adaptive programming
Adaptive program enabled.
Adaptive program disabled.
(Visible when user lock is open)
To change the current user pass code, enter a new code
into this parameter as well as
code. A warning will be active until the new pass code is
confirmed. To cancel changing the pass code, close the
user lock without confirming. To close the lock, enter an
invalid pass code in parameter
activate parameter
196.08 Control board
the power.
See also section
User lock
New user pass code.
(Visible when user lock is open)
Confirms the new user pass code entered in
Change user pass
code.
Confirmation of new user pass code.
on page
on page
(page 21).
196.101 Confirm user pass
196.02 Pass
code,
boot, or cycle
(page 37).
196.100
Parameters 137
Def/FbEq16
Off
0
1
-
Off
0
1
-
500us
500
2000
10000
No
0
1
10000000
-
-

Advertisement

Table of Contents