ABB ACS880 Firmware Manual page 49

Diode supply control program
Hide thumbs Also See for ACS880:
Table of Contents

Advertisement

No.
Name/Value
106.25
Drive inhibit status
word 2
Bit
Name
0
Follower drive
1
Application
2
Aux. power
failure
3
Reserved
4
Ref source
parametrization
5...15 Reserved
0000h...FFFFh
106.30
MSW bit 11 sel
False
True
Ext ctrl loc
Other [bit]
106.31
MSW bit 12 sel
False
True
Other [bit]
106.32
MSW bit 13 sel
False
True
Other [bit]
106.33
MSW bit 15 sel
False
True
Other [bit]
Description
Drive inhibit status word 2. This word specifies the
source of the inhibiting signal that is preventing the unit
from starting.
See also parameters
106.18 Start inhibit status
and
106.16 Drive status word
This parameter is read-only.
Description
1 = A follower is preventing the master from starting.
1 = The application program is preventing the drive from
starting.
1 = A control unit auxiliary power failure is preventing the drive
from starting.
1 = A reference source parametrization conflict is preventing
the drive from starting.
Drive inhibit status word 2.
Selects a binary source whose status is transmitted as
bit 11 of
106.11 Main status
0.
1.
External control location selected.
A specific bit in another parameter.
Selects a binary source whose status is transmitted as
bit 12 of
106.11 Main status
0.
1.
A specific bit in another parameter.
Selects a binary source whose status is transmitted as
bit 13 of
106.11 Main status
0.
1.
A specific bit in another parameter.
Selects a binary source whose status is transmitted as
bit 15 of
106.11 Main status
0.
1.
A specific bit in another parameter.
word,
1, bit 1.
word.
word.
word.
word.
Parameters 49
Def/FbEq16
-
1 = 1
Ext ctrl loc
1
2
3
3
False
1
2
3
False
1
2
3
False
1
2
3