Diode supply control program
Hide thumbs Also See for ACS880:
Table of Contents

Advertisement

No.
Name/Value
0000b...1111b
114.06
DI delayed status
0000b...1111b
114.06
DIO delayed status
0000b...1111b
114.08
DI filter time
0.8 ... 100.0 ms
114.08
DIO filter time
0.8 ... 100.0 ms
114.09
DIO1 configuration
Input
Output
114.11
DIO1 output
source
Not energized
Energized
Ready run
Enabled
Started
Ready ref
Warning
Fault
Description
Status of digital input/outputs.
(Visible when
114.01 Module 1 type
Displays the delayed status of the digital inputs on the
extension module. The word is updated only after
activation/deactivation delays (if any are specified).
Bit 0 indicates the status of DI1.
Note: The number of active bits in this parameter
depends on the number of digital inputs on the
extension module.
Example: 0101b = DI1 and DI3 are on, remainder are off.
This parameter is read-only.
Delayed status of digital inputs.
(Visible when
114.01 Module 1 type
Displays the status of the digital input/outputs on the
extension module. This word is updated only after
activation/deactivation delays (if any are specified).
Bit 0 indicates the status of DIO1.
Note: The number of active bits in this parameter
depends on the number of digital input/outputs on the
extension module.
Example: 1001b = DIO1 and DIO4 are on, remainder are
off.
This parameter is read-only.
Delayed status of digital input/outputs.
(Visible when
114.01 Module 1 type
Defines a filtering time for parameter
Filtering time for 114.05.
(Visible when
114.01 Module 1 type
Defines a filtering time for parameter
The filtering time will only affect the DIOs that are in
input mode.
Filtering time for 114.05.
(Visible when
114.01 Module 1 type
Selects whether DIO1 of the extension module is used as
a digital input or output.
DIO1 is used as a digital input.
DIO1 is used as a digital output.
(Visible when
114.01 Module 1 type
Selects a signal to be connected to digital input/output
DIO1 when parameter
114.09 DIO1 configuration
Output.
Output is not energized.
Output is energized.
Bit 1 of
106.11 Main status word
energized when the supply unit is ready to operate.
Bit 0 of
106.16 Drive status word 1
is energized when the supply unit is enabled.
Bit 5 of
106.16 Drive status word 1
is energized when the supply unit is started.
Bit 2 of
106.11 Main status
when the supply unit operation is enabled.
Bit 7 of
106.11 Main status word
energized when a warning is active.
Bit 3 of
106.11 Main status word
energized when a fault is active.
= FDIO-01)
=
FIO-01
or FIO-11)
= FDIO-01)
114.05 DI
status.
=
FIO-01
or FIO-11)
114.05 DIO
=
FIO-01
or FIO-11)
=
FIO-01
or FIO-11)
is set to
(see page 47). Output is
(see page 47). Output
(see page 47). Output
word. Output is energized
(see page 47). Output is
(see page 47). Output is
Parameters 67
Def/FbEq16
1 = 1
-
1 = 1
-
1 = 1
10.0 ms
10 = 1 ms
10.0 ms
status.
10 = 1 ms
Input
0
1
Not
energized
0
1
3
4
5
7
8
9

Advertisement

Table of Contents
loading

Table of Contents