Ddcs Receive - ABB ACS880 Firmware Manual

Diode supply control program
Hide thumbs Also See for ACS880:
Table of Contents

Advertisement

126 Parameters
No.
Name/Value
161.118
Data set 21 data 3
value
0...65535
161.119
Data set 23 data 1
value
0...65535
161.120
Data set 23 data 2
value
0...65535
161.121
Data set 23 data 3
value
0...65535
161.122
Data set 25 data 1
value
0...65535
161.123
Data set 25 data 2
value
0...65535
161.124
Data set 25 data 3
value
0...65535
162

162 DDCS receive

162.51
Data set 10 data 1
selection
None
CW 16bit
External DC meas
signal
Other
162.52
Data set 10 data 2
selection
162.53
Data set 10 data 3
selection
162.54
Data set 12 data 1
selection
None
CW 16bit
Other
Description
Defines the raw data to be transmitted in data set 21
data word 3.
Raw data to be transmitted in data set 21 data word 3.
Defines the raw data to be transmitted in data set 23
data word 1.
Raw data to be transmitted in data set 23 data word 1.
Defines the raw data to be transmitted in data set 23
data word 2.
Raw data to be transmitted in data set 23 data word 2.
Defines the raw data to be transmitted in data set 23
data word 3.
Raw data to be transmitted in data set 23 data word 3.
Defines the raw data to be transmitted in data set 25
data word 1.
Raw data to be transmitted in data set 25 data word 1.
Defines the raw data to be transmitted in data set 25
data word 2.
Raw data to be transmitted in data set 25 data word 2.
Defines the raw data to be transmitted in data set 25
data word 3.
Raw data to be transmitted in data set 25 data word 3.
Mapping of data received through the DDCS link.
Selects the location into which the value of data set 10
data word 1 is written.
None.
Virtual address for 16-bit control word.
External DC voltage measurement signal. Value is stored
to parameter
120.60 DC voltage external
Source selection (see
Terms and abbreviations
39).
Selects the location into which the value of data set 10
data word 2 is written.
For the selections, see parameter
data 1
selection.
Selects the location into which the value of data set 10
data word 3 is written.
For the selections, see parameter
data 1
selection.
Selects the location into which the value of data set 12
data word 1 is written.
For the selections, see parameter
data 1
selection.
None.
Virtual address for 16-bit control word.
Source selection (see
Terms and abbreviations
39).
unscaled.
on page
162.51 Data set 10
162.51 Data set 10
162.51 Data set 10
on page
Def/FbEq16
0
1 = 1
0
1 = 1
0
1 = 1
0
1 = 1
0
1 = 1
0
1 = 1
0
1 = 1
None
0
1
30780
-
None
None
None
0
1
-