10. Specifications

Bridge voltage
Signal input range
Equivalent
input/
TEDS
Precision
Load
A/D conversion
Low-pass filter
D/A output
TEDS function
Pulse
Displacement
Voltage
Display
Indicator value
External input and output
signals
Power supply
Operating temperature range
Storage temperature range
Operating humidity range
Applicable standards
External dimensions (W × H × D)
Weight
o Specifications and appearance are subject to change without notice.
o Weight and dimensions are approximate.
o Illustrations in this document might differ slightly from production models.
98
DC, 2.5/5/10 V, ±10% (30mA current maximum, can be used with remote sense)
±3.2 mV/V
Calibration range
0.1 mV/V – 3.0 mV/V
Calibration
Within 0.1% F.S. (when using 1m standard Ø8, 6-core shielded cable with 350Ω
precision
impedance, 10V BV and 3.0mV/V setting)
Linearity
Within 0.01% F.S. +1 digit (when input is 3.0 mV/V)
Zero drift
Within 0.5 μV/°C (input conversion value)
Gain drift
Within ±0.005% F.S./°C
24-bit, 5000 times/second, 25000 times/second
Select 3, 10, 30, 100, 300, 1000 Hz(−6 dB/oct) or Off
Output with same frequency as A/D conversion, isolated output, ±1–±10V output
(set in 1V steps) and about 1/59000 resolution (when set to ±10 V), or 4–20mA
current output and about 1/43000 resolution
IEEE1451.4 class 2 mix mode interface
Pulse type
A/B phase or A phase, differential square wave (RS-422 conformance)
Maximum input
2 MHz
frequency
Maximum count
15000000
number
Power output
+5 V ±10%, 150 mA
Input
±5.2 V
Low-pass filter
10/30/100/300 Hz
Power output
DC 12V ±10%, 250 mA
4.3" color LCD (480×272)
Display range
−32000 to 32000
Decimal point
Display position selectable
Times displayed
4 times/second
Differential pulse position sensor (A phase, B phase), force backlight lighting, pre-
vent touchscreen operation, force reset, work switching (4-bit), switch zone, clear
Input
results (reset measurement results), enable/disable judgment output, start/stop
measurement, zero balance displacement, digital zero
Isolated from main unit circuits using a photocoupler
Load judgment output (HH, HI, OK, LO, LL), displacement judgment output (HI,
Output
OK, LO), load cell error, measurement complete, trigger output (1, 2)
Open collector output (isolated from main unit circuits using a photocoupler)
RS-232C
RXD, TXD
Ratings: 24V DC ±10%, 13 W
0°C to 40°C
−20°C to 60°C
85% RH or less (without condensation)
CE marking, FCC (Class A), UL61010-1, UKCA marking
Approximately 114 mm × 96 mm × 140 mm (without protrusions)
About 960 g