ZONE SWITCHING
Set the zone selection method.
PRESET: Use the work setting.
EXT. INPUT: Use the "Switch zone" signal from the control
signal input terminal (CONTROL connector) to
change zones (page 56).
o Zone switching will occur in order from
the lowest numbered zone set to "ENABLE"
in advance. Settings other than the zone
range will be used as is.
INDICATOR VALUE
Select the value shown as the indicator value on the Home
Screen.
To hold an indicator value at a judgment value in a specific
zone, select the zone.
Zone number (1, 2, 3, 4, 5)
Zone number to set
Zone # (number of selected tab)
ENABLE: Use this zone for judgment.
DISABLE: Do not use this zone for judgment.
JUDGE. METHOD (judgment method)
Select the hold method used when measurement data is
in the zone.
CHECK
The button color shows the zone display color. When the
zone is enabled, touch to show the current zone on the
graph.
ZONE RANGE
Set the range of the X axis.
The X axis unit is set on the SENSOR screen.
This is enabled when ZONE SWITCHING is "PRESET".
ATTENTION
The maximum zone range values are "X AXIS FULL SCALE"
for the X axis (page  29) and "MAX. DISP. VALUE" for the Y
axis (page 40).
LOAD HIGH (HI)/LOW (LO)
Set the Y axis management values in the zone.
DISPLACEMENT (HI)/(LO)
For X axis displacement, set the displacement manage-
ment values in the zone.
ATTENTION
For details about the method for judging displacement,
see "4-6-4-2. Judgment method" on page 58.
To conduct displacement judgment, the X axis must be set
to displacement, and the displacement high and low limit
values must be set within the zone.
Example of multi-zone judgment display
o If a valid value is set as the displacement management value,
a dotted vertical line will appear in the zone.
4. Settings
57