6. Communication functions
6-1-2-8. Work
Content
Work number
Switch work (WORK SWITCHING)
Copy work
Measurement starting condition
Measurement
Measurement starting level
trigger
Measurement stopping condition
Measurement stopping level
Enable HHLL
HH
Continuous
HI
judgment
LO
LL
Enable/Disable waveform comparison
Band judgment
(WAVEFORM COMP.)
Zone switching
Zone judgment
Indicator value display (INDICATOR VALUE)
Set zone number
Enable zone
Zone range starting point
Zone range ending point
Load high limit (HI)
Load low limit (LO)
Displacement high limit (HI)
Displacement low limit (LO)
Judgment method
Zone settings
Maximum/minimum
Inflection point
(INFLECTION)
76
Command No. Setting item
7000
7001
7002
7003
7004
7005
7006
7010
7011
7012
7013
7014
7100
7101
7102
7200
7201
7202
7203
7204
7205
7206
7207
7208
Load difference
7211
(LOAD DIF.)
Scaling factor
7212
Number of detections
7213
(COUNT)
Detection starting
7220
load (STARTING LOAD)
Detection extent A
7221
(WIDTH A)
Detection extent B
7222
(WIDTH B)
Load difference
7223
(LOAD DIF.)
Offset extent
7224
(OFFSET)
1–16 (enabled only during manual selection)
0: Manually, 1: External input (EXT. INPUT)
0: All, 1–16: Work number
0: EXT. SIGNAL, 1: EXT. & LOAD, 2: EXT. & DISP, 3: LOAD
1, 4: LOAD z, 5: DISPLACE. 1, 6: DISPLACE. z
±99999
0: EXT. SIGNAL, 1: EXT. or LOAD (EXT. | LOAD),
2: EXT. or DISP. (EXT. | DISP.), 3: EXT. or TIME (EXT. | TIME)
±99999
0: Disabled, 1: Enabled
±99999
±99999
±99999
±99999
0: Disabled, 1: Enabled
o If no reference waveform has been set, it will not
become enabled.
0: Preset, 1: External input
0: Input value, 1–5: Zone number
1–5 (resets to 1 when power turned on/off )
o The zone set by this can be changed with the
following commands.
0: Disabled, 1: Enabled
0–99999
0–99999
±99999
±99999
0–99999
o This can be set when the X axis is set to
displacement.
0–99999
o This can be set when the X axis is set to
displacement.
0: Constant comparison, 1: Sample, 2: Peak, 3: Bottom,
4: Peak-to-peak, 5: Average value, 6: Maximum,
7: Minimum, 8 Inflection point
±99999
00–99 (input without decimal point) (0.0–9.9)
1–10
±99999
1–9999
1–9999
±99999
0–99