Although not provided with the UPS, a battery system is required to provide emergency short-term backup
power to safeguard operation during brownouts, blackouts, and other power interruptions. The battery system
should be equipped with lead–acid batteries. An external battery disconnect switch must be used.
The UPMs may be powered with either a common or separate battery system. In a common battery system,
single and multiple UPMs are powered from one common battery source. In a separate battery system,
multiple UPMs are each powered from separate battery sources.
UPMs in distributed bypass and parallel systems must use a separate battery system.
Consult the Eaton
Manual (P-164000580) for specifics on battery cabinet usage with the 9395P-1200.
A supplemental 48 Vdc shunt trip signal for the battery disconnect device is provided by the UPS, but is not
required for normal operation.
NOTE
1 1 . . 5 5
U U s s i i n n g g T T h h i i s s M M a a n n u u a a l l
This manual describes how to install and operate the Eaton 9395P-1200 (1200 kVA, 1200 kW) UPS. Read and
understand the procedures described in this manual to ensure trouble-free installation and operation. In
particular, be thoroughly familiar with the REPO procedure (see paragraph ).
The information in this manual is divided into sections and chapters. The system, options, and accessories
being installed dictate which parts of this manual should be read. At a minimum, Chapters 1 through 4 and
Chapter 7 should be examined.
Read through each procedure before beginning the procedure. Perform only those procedures that apply to the
UPS system being installed or operated.
1 1 . . 6 6
C C o o n n v v e e n n t t i i o o n n s s U U s s e e d d i i n n T T h h i i s s M M a a n n u u a a l l
This manual uses these type conventions:
Bold type highlights important concepts in discussions, key terms in procedures, and menu options, or
represents a command or option that you type or enter at a prompt.
Italic type highlights notes and new terms where they are defined.
Screen type represents information that appears on the screen or LCD.
Icon
[Keys]
In this manual, the term UPS refers only to the UPS cabinet and its internal elements. The term UPS
system refers to the entire power protection system – the UPS cabinet, the battery cabinet, and options or
accessories installed.
®
Power Xpert
®
9395/9395P Integrated Battery Cabinet (Model I085 and 1085HR) Installation
The Eaton 9395P-1200 system can trip a maximum of six battery cabinets total. This
applies to both the 1085 standard and High Rate series batteries. If more than six
battery cabinets in total are needed in a separate UPM battery configuration, DO NOT
hook up the shunt trips.
Description
Information notes call attention to important features or instructions.
Brackets are used when referring to a specific key, such as [Enter] or [Ctrl].
Eaton
®
Power Xpert
®
9395P-1200 Installation and Operation Manual 164000500—Rev 11
Introduction
7

Advertisement

Table of Contents
loading

Table of Contents