Display During Normal Operation - Pilz PSEN sc L 3.0 08-12 Series Operating Manual

Hide thumbs Also See for PSEN sc L 3.0 08-12 Series:
Table of Contents

Advertisement

Operation
11.2

Display during normal operation

Message in the display
Icon
Text
CLEANW2
DLDNC
ITLOCK1
INPUTCF1
NOCONF
MUTING
OVERRIDE
Operating Manual PSEN sc L 3.0/5.5 08-12
1005056-EN-06
Status
The font panel of the safety laser
scanner is contaminated and it must
be cleaned to ensure normal opera-
tion.
Download of a configuration or a re-
port
The status of the network is checked
Safety laser scanner in interlock con-
dition
Faulty input
No configuration available
Muting on OSSD1 is active.
The OSSDs are in the ON state.
Override is active.
Description/measure
Clean front panel
A configuration or a report is
downloaded.
The status of the safety laser
scanner in the network is
checked.
The safety laser scanner is in
interlock condition. Normal op-
eration is possible only after a
successful restart of the safety
laser scanner.
Faulty input, e.g. wrong number
of inputs that are used for
switching the zone sets.
No configuration for the safety
laser scanner could be found.
| 98

Advertisement

Table of Contents
loading

This manual is also suitable for:

Psen sc l 5.5 08-126d0000126d000013

Table of Contents