Project configuration
}
Change the inclination of the safety laser scanners.
}
Place an opaque object between the safety laser scanners
6.7
Dust filtration
The safety laser scanner has a dust filtration function. This changes the sensitivity of the
safety laser scanner, and the availability in dusty environments can be improved.
There are two levels:
}
Low for clean environments/low dust formation
}
High for contaminated environments/strong dust formation
The default setting is low.
Depending on the degree of dust filtering, it is necessary to consider an allowance for cal-
culating the safety distance when installing the safety laser scanner near intense light
sources or reflective surfaces (see
surfaces [
Operating Manual PSEN sc L 3.0/5.5 08-12
1005056-EN-06
Distance to intense light sources and to reflective
49]).
| 48