Muting In Two Directions - Pilz PSEN sc L 3.0 08-12 Series Operating Manual

Hide thumbs Also See for PSEN sc L 3.0 08-12 Series:
Table of Contents

Advertisement

Project configuration
6.13.2

Muting in two directions

}
The muting status occurs
– If the signal at the second muting input Muting 12 switches to High after muting input
– The delay between the two signal changes is within the configurable range Muting
}
The muting state is ended
– When the configured time is reached or
– When the signal at one of the two muting inputs switches to low and
– the internal delay of max. 30 ms has elapsed.
Fig.: Timing diagram T-muting
Legend
Operating Manual PSEN sc L 3.0/5.5 08-12
1005056-EN-06
Muting 11 has also switched to high (or muting input Muting 11 switches to High
after muting input Muting 12) and
activation delay [ms]. The max. delay can be configured for between 1 and 16
seconds.
Input
On
Muting 11
Off
On
Input
Muting 12
Off
Muting
On
function
Off
t
Delay between Muting 11 and Muting 12 (configurable from 1-16 s)
1
t
Duration of the muting state (max. up to the configured timeout)
2
t
Internal delay before the muting state is ended (max. 30 ms)
3
t
Delay between Muting 11 and Muting 12 (configurable from 1-16 s)
4
t
Duration of the muting state (max. up to the configured timeout)
5
t
2
t
t
1
3
t
5
t
t
4
| 54