Project configuration
6.1.2
Horizontal application with stationary danger zone
A horizontal application has been achieved when the safety laser scanner is aligned at an
angle of max. 30° with the floor level.
Fig.: Schematic representation minimum distance from the start of the protected area to the danger
zone
Legend
[1] Danger zone
[2] Area covered by the laser beam
[3] Safety laser scanner
[4] Minimum distance to the danger zone (corresponds max. to the operating range of
[5] Safety allowance Z
[6] Wall
The following applies for these applications:
S = K * (t
Operating Manual PSEN sc L 3.0/5.5 08-12
1005056-EN-06
[6]
[6]
[3]
the safety laser scanner)
for the distance from fixed objects or walls
T
+ t
) + Z
+ Z
+ C
1
2
T
R
[2]
[4]
[1]
[5]
| 33