PSENscan Configurator
4. Select Monitoring and check the downloaded configuration.
5. Select Download configuration and Accept or Reject the downloaded configuration:
}
Click Accept to activate the downloaded configuration in the connected device and reject
the existing configuration on the connected device.
}
Click Reject to reject the downloaded configuration in the connected device and continue
to use the existing configuration on the connected device. The downloaded configuration
in the connected device will be deleted.
9.4

Create backup copy of a configuration

For restoring an existing configuration (see
backup copy of this configuration.
Procedure:
}
Select Project -> Save.
The dialogue box for saving is opened. Please enter a name for the MIB file.
The MIB file includes all the data for configuration.
9.5

Change password

Prerequisites
}
There is a connection to the safety laser scanner.
Procedure:
1. In the PSENscan Configurator, select Device -> Settings -> Change access rights
and password.
Enter the current password and click "OK".
2. Enter the new password twice and select the access rights for the password.
Enter the new password in the field New password. Repeat the password in the field
Check new password. Select the access rights for the password and confirm with OK.
9.6

Reset password

Prerequisites
}
There is a connection to the safety laser scanner.
Procedure:
1. In PSENscan Configurator, select Device-> Settings -> Reset password.
Take down the counter shown and the serial number of the safety laser scanner. Do
not close the window unless you have a new password.
2. For resetting the password, please contact Pilz.
Name the counter shown and the serial number of the safety laser scanner.
You will receive a new password.
3. Enter any text in the Reset password window and click OK.
You can access the safety laser scanner again.