Project configuration
6.15
Rest condition
The safety laser scanner can only be switched to the rest condition, when
}
more than one zone set is configured
}
no safety or warning zones are configured in the relevant zone set.
The settings in a configuration remain saved.
Forms drawn in a configuration are deleted when the rest condition is activated.
During the rest condition, the following actions are not possible:
}
Changes to the configuration
}
Update firmware
}
Changes of network settings (e.g. IP address)
Maximum power consumption of the safety laser scanner in normal operation and in
the rest state
Product type
PSEN sc L 3.0/5.5 08-12 series
Operating Manual PSEN sc L 3.0/5.5 08-12
1005056-EN-06
Consumption in normal opera-
tion
(without load)
300 mA
Consumption in rest state
200mA
| 62