Safety checks, maintenance and repair
12.3.2
Exchange of a memory module
When exchanging a memory module, you can use a memory module without saved config-
uration or a memory module where a configuration is already saved. This configuration can
be restored for use in the safety laser scanner.
Note:
The memory module must only be uninstalled when the supply voltage is switched off.
Procedure:
1. Switch off the safety laser scanner.
2. Turn the safety laser scanner PSEN sc L 3.0/5.5 08-12 series for better access to the
memory module.
3. Loosen the M3 screws of the protective cover and remove the protective cover.
The screws are secured against loss and they cannot be removed.
Operating Manual PSEN sc L 3.0/5.5 08-12
1005056-EN-06
| 111