Operation; Display Of The Monitoring Status - Pilz PSEN sc L 3.0 08-12 Series Operating Manual

Hide thumbs Also See for PSEN sc L 3.0 08-12 Series:
Table of Contents

Advertisement

Operation

11
Operation
11.1

Display of the monitoring status

Icon
Valid config-
Configura-
uration
tion not yet
accepted
Operating Manual PSEN sc L 3.0/5.5 08-12
1005056-EN-06
Status
Device is switched on and opera-
tional
Warning zone has been violated
Safety zone has been violated
Change detected in the reference
outline
Description/measure
A violation of the warning zone has
been detected. The configured ac-
tion for a violation of the warning
zone has been triggered.
The area of violation is marked out-
side the semicircle with the yellow
beams.
A violation of the safety zone has
been detected. The OSSDs are in
the OFF state.
The area of violation is marked out-
side the semicircle with the red
beams.
A violation of the reference outline
has been detected. The area of
change is marked outside the semi-
circle with the blue beams.
Check the cause for the change and
eliminate the cause or adapt the ref-
erence outline.
| 97