6.13.4

Dynamic muting

When Activate muting is selected for an input, muting can be activated and deactivated
dynamically.
}
Conditions for the occurrence of muting
– One of the configurable inputs/outputs is connected to a controller and receives a
– When configuring the inputs, Activate muting is configured for this input in
– the first sensor has detected conveyed material and the second sensor also detected
6.14

Override

The override function can be used for the three types according to the timing diagrams.
}
Single-channel pulses
}
Activation is edge-triggered
}
Activation is signal-triggered (only when using the 12-pin connection)
The Override function can only be activated when the input signals are controlled in accord-
ance with the timing diagrams.
Protective zone
Single-channel
Fig.: Timing diagram for override function single-channel pulses
Operating Manual PSEN sc L 3.0/5.5 08-12
1005056-EN-06
high signal from there if muting is to be activated
PSENscan Configurator
it max. 4 s afterwards
At
Off
At
Status
Override
Off
24 V
Pulse
0 V
< 1 s
< 1 s
< 1 s
< 1 s
< 1 s
< 1 s
t
2 s