Connection To Psenscan Configurator - Pilz PSEN sc L 3.0 08-12 Series Operating Manual

Hide thumbs Also See for PSEN sc L 3.0 08-12 Series:
Table of Contents

Advertisement

Wiring
7.7

Connection to PSENscan Configurator

Note:
}
Ensure that the software PSENscan Configurator is installed on the configuration PC.
We recommend that you always use the latest version (download from www.pilz.com)
}
Ensure that the safety laser scanner is switched off when creating a connection to the
configuration PC.
100BaseTX cable
Bit rate
Max. segment length
Medium
Connection
Topology
*1
For use in an industrial environment, Pilz recommends double-shielded twisted pair cables
(S/STP). Only shielded RJ45 connectors should be used.
*2
Twisted pair cables (TP cable) consist of twisted core-pairs. Twisted pair cables are divided
into categories in accordance with their electrical features (attenuation, cross-talk). Cat-
egory 5 cables are specified for transferring data with Pilz Ethernet interfaces.
TP cables for Ethernet applications generally have an impedance level of 100 Ohm.
Operating Manual PSEN sc L 3.0/5.5 08-12
1005056-EN-06
100 MBit/s
100 m
STP
*1
(shielded twisted pair)
2 pairs
*2
Category 5
4-pin M12 male connector /4-pin RJ45 male
connector
Point-to-point/hub
(hub, switch)
| 70