Project configuration
6.2
Calculation of the overall response time
The overall response time results from the response time t1 (see
details [
Overall response time T
T
overall
t
1
t
multiple
t
Subscriber
In a multiple evaluation = 3 the allowance is T
Each further increase of the multiple evaluation by 1 increases the allowance T
ms.
Operating Manual PSEN sc L 3.0/5.5 08-12
1005056-EN-06
121]), plus an allowance of 30 ms t
overall
= t
+ t
t
1
multiple +
Subscriber
Response time t1 (see
Allowance 30 ms for each further rotation of the safety laser scanner (for mul-
tiple evaluation > 2)
Allowance of 10 ms per subscriber
for each scan > 2.
multiple
Technical details [
121])
= 30 ms.
multiple
Technical
by 30
multiple
| 41