Installation and alignment
Prerequisites
}
Mounting surface with 2 through-holes for screws M5x10 mm, distance 73 mm horizont-
ally towards each other for fixing the bracket of the safety laser scanner.
}
The mounting surface has to be accessible from both sides for installation.
Procedure:
1. Turn the safety laser scanner when the safety laser scanner is to be operated with the
top side down.
2. Use two M5 screws to fix the safety laser scanner to the mounting surface. Tighten the
screws to 3 Nm.
8.3
Installation of the protective bracket PSEN sc bracket H at
the safety laser scanner
For easy and flexible installation of the safety laser scanner, the safety laser scanner is
fixed to a protective bracket PSEN sc bracket H (see
accessories [
damage by falling objects.
With this protective bracket, the safety laser scanner can be used in both brackets
PSEN sc bracket PR (for inclination to the side or upwards and downwards) or
PSEN sc bracket P (for inclination upwards and downwards) (see
Accessories [
1. Turn the safety laser scanner when the safety laser scanner is to be operated with the
top side down.
2. Fix the PSEN sc bracket H at the rear of the safety laser scanner with two M5 screws
and tighten both screws with 3 Nm.
Legend
[1]
[2]
[3]
Operating Manual PSEN sc L 3.0/5.5 08-12
1005056-EN-06
126]). The protective bracket protects the safety laser scanner against
126]).
[2]
PSEN sc bracket H (protective bracket for safety laser scanner)
M5 screws for fixing the PSEN sc bracket H at the safety laser scanner
PSEN sc bracket H installed at the safety laser scanner
[1]
[3]
Order reference
Order reference: