Installation and alignment
8.6

Installation for inclination upwards and downwards

}
The setting of the angle of inclination of the safety laser scanner is not changed when ex-
changing the safety laser scanner.
Prerequisites
}
PSEN sc bracket P (see
}
Mounting surface with 2 drill holes, 10 mm deep, distance 73 mm horizontally to each
other for attaching the PSEN sc bracket P
}
The protective bracket PSEN sc bracket H must already be attached to the safety laser
scanner (see
scanner [
Procedure:
Legend
[1] Adjusting disc for angle of inclination
[2] Set screw for adjusting disc for angle of inclination
[3] Fixing screws for safety laser scanner
[4] Fine adjustment screws for the incline of the safety laser scanner
[5] PSEN sc bracket P
[6] Fixing screws for fixing to the mounting surface
Procedure:
1. Fix PSEN sc bracket P with the fixing screws [6] to the mounting surface and tighten
the fixing screws [6] alternately and evenly with 3 Nm.
2. Fix the adjusting disc for angle of inclination [1] with the set screws and washers [2] on
the PSEN sc bracket P (right or left).
3. Align the middle of the adjusting disc for angle of inclination [1] with the center of the fix-
ing for the safety laser scanner [3] and tighten the set screw for the adjusting disc for
angle of inclination [2] with 2,5 Nm.
Operating Manual PSEN sc L 3.0/5.5 08-12
1005056-EN-06
Order references [
Installation of the protective bracket PSEN sc bracket H on the safety laser
74]).
[4]
[1]
[2]
[3]
126])
[6]
[4]
[3]
[5]