Muting In One Direction - Pilz PSEN sc L 3.0 08-12 Series Operating Manual

Hide thumbs Also See for PSEN sc L 3.0 08-12 Series:
Table of Contents

Advertisement

Project configuration
Fig.: Distances between muting sensors - Cross muting
Legend
[1] Safety laser scanner
A1 First muting sensor on the input side, connected to Muting 11
B1 Second muting sensor on the input side, connected to Muting 12
d2 Distance that the object covers from the first muting sensor A1 to the second mut-
6.13.3

Muting in one direction

}
The muting status occurs
– If the signal at the second muting input Muting 12 switches to High after muting input
– The delay between the two signal changes is within the configurable range Muting
}
The muting state is ended
– When the configured time is reached or
– after a multiple of the delay between the activation of the two muting sensors.
Operating Manual PSEN sc L 3.0/5.5 08-12
1005056-EN-06
ing sensor B2 in max. 4 s
V Speed at which the object is moving
NOTICE
Faulty application of L-muting
– Only use L-muting to remove material from the danger zone.
Muting 11 has also switched to high (or muting input Muting 11 switches to High
after muting input Muting 12) and
activation delay [ms]. The max. delay can be configured for between 1 and 16
seconds.
The Factor activation delay can be selected between 2 and 16.
[1] A1
B1
V
d2
| 57