First commissioning
18. Select Download configuration to device, to transfer the configuration to the device.
Click Accept to activate the downloaded configuration in the connected device and re-
ject the existing configuration on the connected device.
Save the report in PDF format.
Click Reject to reject the downloaded configuration in the connected device and con-
tinue to use the existing configuration on the connected device. The downloaded con-
figuration in the connected device will be deleted.
10.4

Testing

Before finally commissioning the safety laser scanner after the installation and alignment, fi-
nal inspections must be carried out.
Check safety function of the safety laser scanner
Procedure:
As a test piece, use an opaque object with a height of at least 300 mm and a diameter that
corresponds to the selected detection capability.
}
Move the test piece at various points along the limits of the safety zone into the safety
zone:
The OSSDs must switch to the OFF state with each entry of the test piece into the safety
zone.
}
Switch off the safety laser scanner.
Both OSSDs have to automatically switch to the OFF state. The machine in the mon-
itored danger zone is switched off and in cannot be started.
}
Behaviour when the safety zone is free again
Remove the test piece from the safety zone.
– Automatic restart
– Manual restart
Supplementary test step for vertical applications
Change the position of the reference points beyond the tolerance range of the reference
points:
The OSSDs must switch to the OFF state with each change of the reference point beyond
the tolerance range.
Operating Manual PSEN sc L 3.0/5.5 08-12
1005056-EN-06
INFORMATION
This inspection may only be carried out by qualified personnel.
The safety laser scanner starts automatically and the OSSDs switch to the ON state.
The OSSDs remain in OFF state and they only switch to the ON state when the start
pushbutton was operated for at least 0.5 s and a maximum of 5 s and released again.