6.5

Area with limited detection capability

In the area of max. 100 mm before the laser scanner there is an areas with limited detec-
tion capability.
Note:
}
Ensure that the area is not part of the danger zone.
}
Install the safety laser scanner so that no objects can enter the zone with limited detec-
tion capability.
Legend
6.6

Installation of several adjacent safety laser scanners

When safety laser scanners must be installed in an area, it must be ensured that the safety
laser scanners do not influence each other.
This can be achieved in two ways:
With coding [
detection capability configuration,
Without coding: Install safety laser scanner at various heights or inclinations.
}
Change the height of the safety laser scanners
Operating Manual PSEN sc L 3.0/5.5 08-12