Install Psenscan Configurator; Ethernet Connections; Factory Default Settings For The Ip Addresses; Create Firewall Rule - Pilz PSEN sc L 3.0 08-12 Series Operating Manual

Hide thumbs Also See for PSEN sc L 3.0 08-12 Series:
Table of Contents

Advertisement

PSENscan Configurator
9.2.2

Install PSENscan Configurator

Procedure:
1. Download the software PSENscan Configurator from the download area on the Pilz
homepage under http://www.pilz.com/support/downloads/.
2. Double-click on the unpacked file.
The software PSENscan Configurator is installed.
The installer will guide you through the installation.
9.2.3

Ethernet Connections

9.2.3.1

Factory default settings for the IP addresses

The factory-set default of the IP address of the safety laser scanner: 192.168.0.10.
9.2.3.2

Create firewall rule

A firewall or any other security mechanisms on the PC and network may prevent the
PSENscan Configurator from communicating correctly with the connected devices. In this
case, it will be necessary to adjust the security settings and firewall settings.
Firewalls allow access to explicitly registered programs.
PSENscan Configurator must have access to the Private profile.
Operating Manual PSEN sc L 3.0/5.5 08-12
1005056-EN-06
INFORMATION
To ensure that PSENscan Configurator functions correctly, the files and dir-
ectories in the installation directory of PSENscan Configurator must not be
modified manually once installed (e.g. with the Windows Explorer or a text
editor).
INFORMATION
Use the correct IP address
A second IP address has been set up for internal functions of the safety
laser scanner. This address always follows directly after the IP address spe-
cified in the network settings.
Example: First address = 192.168.0.10, second address = 192.168.0.11
– Ensure that the subsequent IP address is not used by any other net-
work subscriber.
| 83