First commissioning
10
First commissioning
10.1
Requirements for commissioning
Note:
}
Ensure that the window of the safety laser scanner is clean, intact and without finger-
prints.
10.2
System connection
Make sure that the selected evaluation device has the following property:
}
OSSD signals are evaluated through 2 channels with plausibility monitoring
Fig.: Dual-channel connection of the safety laser scanner with 8-pin male connector on the input cir-
cuit of an evaluation device (1 zone set, warning message, automatic restart)
Operating Manual PSEN sc L 3.0/5.5 08-12
1005056-EN-06
CAUTION!
Deterioration in the detection of safety zone violations
If the safety laser scanner is commissioned under deviating conditions,
there may be a deterioration in the detection of safety zones violations.
External
supply voltage
24 V
Evaluation device
A1
A2
Input circuit
I1 (FS)
I2 (FS)
Indicator light unit
0 V
4 n.c.
3 n.c.
1
2 24 V
7
6
5
8
Warning message
0 V
OSSD 2
OSSD 1
F.E.
PSENscan
| 86