Diagnostic Information; Error - Pilz PSEN sc L 3.0 08-12 Series Operating Manual

Hide thumbs Also See for PSEN sc L 3.0 08-12 Series:
Table of Contents

Advertisement

Operation
11.3

Diagnostic information

11.3.1

Error

Message in the display
Icon
Text
BKP FAILED
CLEANW1
DEVICE
EMPTY
EDM
INPUTCF1
INPUTCF2
INTFx
X = 1 -17 incl.
INTF18
Operating Manual PSEN sc L 3.0/5.5 08-12
1005056-EN-06
Error/cause
Creating a backup copy of a config-
uration has failed.
The front panel of the safety laser
scanner must be cleaned.
No configuration is stored in the
safety laser scanner.
EDM configured incorrectly.
Error in the configuration or the wir-
ing.
Configuration error.
An error occurred during the system
test.
An error occurred during the system
test.
Description/measure
}
Restart creating a backup
copy [
96]
or
}
Create a new configuration in
PSENscan Configurator [
Clean front panel
}
Create a new configuration in
PSENscan Configurator
}
Restore a configuration from the
memory module [
Check the wiring of the
EDM [
63].
Make sure that the configuration of
the EDM matches the technical de-
tails of the EDM.
If the error persists, please contact
Pilz.
Check whether the
wiring [
and the
configuration [
match.
In the configuration, check the con-
figured state transitions and switch-
ing operations.
Ensure that no outputs with test
pulses are connected to the inputs of
the safety laser scanner
Perform a
reset of the safety laser
scanner [
107].
If the error persists, please contact
Pilz.
Perform a
reset of the safety laser
scanner [
107].
If the error persists, please contact
Pilz.
87].
or
106].
63]
87]
will
| 99

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the PSEN sc L 3.0 08-12 Series and is the answer not in the manual?

This manual is also suitable for:

Psen sc l 5.5 08-126d0000126d000013

Table of Contents