First commissioning

9
First commissioning
9.1

Requirements for commissioning

Please note:
}
Ensure that the window of the safety laser scanner is clean, intact and without finger-
prints.
9.2

System connection

Make sure that the selected evaluation device has the following property:
}
OSSD signals are evaluated through 2 channels with plausibility monitoring
Fig.: Dual-channel connection of the safety laser scanner with 8-pin male connector on the input cir-
cuit of an evaluation device (1 zone set, warning message, automatic restart)
Operating Manual PSEN sc M 3.0/5.5 08-12
1005055-EN-03
CAUTION!
Detection of safety zones being violated deteriorates
If the safety laser scanner is commissioned in deviating conditions, the de-
tection of the safety zones being violated may deteriorate.
– Ensure that the conditions for commissioning are met.
External supply voltage
24 V
Evaluation device
24 V
0 V
Input circuit
Indicator light unit
0 V
4 n.c.
3 n.c.
1
2 24 V
7
6
5
8
Warning message
0 V
OSSD 2
OSSD 1
F.E.
PSENscan