First commissioning
9
First commissioning
9.1
Requirements for commissioning
Please note:
}
Ensure that the window of the safety laser scanner is clean, intact and without finger-
prints.
9.2
System connection
Make sure that the selected evaluation device has the following property:
}
OSSD signals are evaluated through 2 channels with plausibility monitoring
Fig.: Dual-channel connection of the safety laser scanner on the input circuit of an evaluation device
(1 zone set, warning message, automatic restart)
Suitable Pilz evaluation devices are, for example:
}
PNOZmulti for monitoring safety laser scanners
Configure the safety laser scanner in PNOZmulti Configurator as a function element
"Light curtain" with switch type 3.
Operating Manual PSEN sc M 3/5 series
1005055-EN-02
CAUTION!
Detection of safety zones being violated deteriorates
If the safety laser scanner is commissioned in other conditions, the detec-
tion the safety zones being violated may deteriorate.
– Ensure that the conditions for commissioning are met.
External supply voltage
24 V
Evaluation device
24 V
0 V
Input circuit
Indicator light unit
0 V
4 n.c.
3 n.c.
1
2 24 V
7
6
5
8
Warning message
0 V
OSSD 2
OSSD 1
F.E.
PSENscan
| 69