Indication of load

1
Symbol
Low load
Medium load
Highest load
Symbol flashes: PMC regeneration required
Symbol illuminates: PMC regeneration active
1.The symbols are displayed from software version 3.3. In earlier software versions status messages (SPN 3701-001/3701-010/3701-011 or 3700-010/SPN 3700-001) appear in the multifunctional
display.

Particulate matter catalyst indicator lights

Engine
Engine stop
warning
Yellow
Red
On
On
Off
Off
Off
Off
Off
Off
Off
Off
Off
Off
Flashes
Off
Flashes
On
OM 25-3503 us – Edition 4.1 * 2503_3503b340.fm
Description
Exhaust-gas
Regenera-
temperature
tion required
Yellow
Yellow
On
On
Off
Off
Off
On
On
On
On
Off
Off
Off
Off
On
Off
On
Full engine power
Automatic regeneration possible
Full engine power
Automatic or manual regeneration is possible
Reduced engine power
Only manual regeneration is possible
Regenera-
tion disa-
bled
Yellow
After switching on the starter, the indicator lights are
On
checked during the first two seconds.
Off
No malfunction.
Off
Regeneration is required.
Off
Active regeneration. Increased exhaust-gas temperature.
Regeneration is completed. Increased exhaust-gas tem-
Off
perature. System is being cooled. The indicator light goes
out one minute after the end of regeneration.
On
Regeneration is disabled or interrupted.
The load has reached the permissible value. Reduced
Off
engine power. Regeneration is required.
The load has exceeded the permissible value. Reduced
engine power. Drive the machine out of the area with eas-
Off
ily-flammable matter. Stop the engine immediately. Con-
tact a Wacker Neuson service center.
Operation
Effect
Description