Driving The Excavator; Preheating Start Switch; Throttle - Wacker Neuson 2503 Operator's Manual

Track excavator
Table of Contents

Advertisement

3.4 Driving the excavator

Preheating start switch

1
0
2
19
Fig. 75: Preheating start switch

Throttle

A
B
16
Fig. 76: Engine speed control Tier III
A
16
B
Fig. 77: Engine speed control Tier IV
OM 25-3503 us – Edition 4.1 * 2503_3503b320.fm
Position
3
0
1
2
3
On machines with Tier III engines, the throttle 16 controls the engine speed progressively
as follows:
Push throttle 16 upward (A).
Engine speed is reduced.
Push throttle 16 down B.
Engine speed is increased.
On machines with Tier IV engines, throttle 16 controls the engine speed progressively as
follows:
Push throttle 16 upward (A).
Engine speed is increased.
Push throttle 16 down B.
Engine speed is reduced.
Function
Insert or remove the starting key None
ON/machine travel position
Preheats the engine (10 – 15
seconds)
Starts the engine
Operation
Power consumer
All functions are operational
Indicator lights illuminate
Shrill sound
Starter is actuated
Indicator lights must go out
3-11