Manual regeneration

A
Fig. 260
Fig. 260
B
C
E
F
Fig. 261
3-114
Starting manual regeneration
Indicator light B illuminates and indicator light E flashes.
1
Manual regeneration is possible only in this case and has to be started.
Drive the machine out of the danger zone and into a safe area.
Apply the parking brake.
2
Press and hold push button A at least 10 seconds in position 3.
Indicator lights B and C illuminate during regeneration.
3
Interrupting manual regeneration
Press and hold the Regeneration push button at least 3 seconds in position 1.
NOTICE
Possible damage to engine or particulate filter.
• Perform a complete regeneration cycle
NOTICE
Fire hazard in the exhaust system.
• There must be no easily flammable material in the direct vicinity of the
exhaust system, in particular near the end pipe.
• Do not perform manual regeneration in environments with easily flammable
material.
Regeneration not performed – stopping the machine
Engine power is reduced if indicator lights B and F illuminate and if indicator light E
flashes.
Stop the engine immediately and contact a Wacker Neuson service center.