Replace Blade In Rack - Fujitsu 1FINITY L100 User Manual

Table of Contents

Advertisement

System Maintenance
Equipment Replacement
Step 10
Clean the optical connectors on the optical fibers.
Caution: Optical connector performance is affected by dust. Clean all connectors before reconnecting the
cables. Keep the ends of fiber-optic cables covered when the cables are not in use.
Step 11
Remove the optical connector covers, if necessary, and carefully press the LC connector tab on each of the I/O
fiber-optic cables to carefully install each cable into the connector.
Step 12
Are the applicable port LEDs on the PIU lit green?
If YES:
Continue with next step.
If NO:
Call Fujitsu at 1-800-USE-FTAC (1-800-873-3822) for technical assistance.
Step 13
Retrieve alarms.
Command:
> show alarms alarm-list
Step Result:
Clear any alarms and standing conditions currently being reported on the NE related to the replacement of the
module. If unable to clear the alarms, call Fujitsu at 1-800-USE-FTAC (1-800-873-3822) for technical assistance.
✓ 
This task is complete.
8.3.4

Replace Blade in Rack

Prerequisite:
■ Power cables removed from the power terminal adapter (AC00-SD11) on the rear of the blade
■ An appropriate ESD wrist strap worn by user and properly grounded to avoid ESD damage during installation
or removal
■ All fibers removed from the blade and appropriately labeled
■ If used, all RJ-45 cables removed from the blade and appropriately labeled
·
Release 19.1.1
Issue 1.1, May 2021
368
Fujitsu and Fujitsu Customer Use Only

Advertisement

Table of Contents
loading