System Feature Administration
Caution: The system zeroization process can take up to 2 hours to complete. Do not power down the
system during this 2-hour time frame and until communication can be reestablished with the blade after
the zeroization process.
Command:
> request zeroize-system
Output:
The system will be reset to the factory status and cannot be recovered. It will
take a couple of hours to complete. Really want to do this? [no,yes]
Step 3
Enter yes to start zeroization of system.
Output:
status Successful
status-message Zeroization of system has started.
Step Result:
The blade is reset to the factory default software status. The blade reboots after 3...6 minutes.
Note: sysZeroizationCompleted alarm is raised before the system is going down for reboot.
Step 4
After the system zeroization process is completed and the system reboots, reestablish communication with the
blade.
✓ 
This task is complete.
6.6.8

Configure AINS

User can specify the target port for configuring AINS.
Step 1
Retrieve systemwide provisionable timeout.
Command:
> show system sys-vstimer
Step 2
Provision system valid signal timer (VSTIMER).
Note: Supported values for VSTIMER are 00-01 to 48-00.
Command Example:
% set system sys-vstimer 08-00
·