Ztpbootinprogress; Secondary Database Alarms And Events - Fujitsu 1FINITY L100 User Manual

Table of Contents

Advertisement

System Maintenance
Trouble Clearing

ztpBootInProgress

Entity Type
COM
8.1.7

Secondary Database Alarms and Events

Entity Type
EQPT (shelf AID)
COM
COM
·
Release 19.1.1
Issue 1.1, May 2021
Service
Severity
Direction
Affect
minor
non–service-
n/a
affecting
Probable Cause
A ZTP Boot is in progress.
Service
Severity
Direction
affected
warning
non–service-
n/a
affecting
Probable Cause
Raised when the secondary storage media is
faulty or is not present on a given blade.
minor
non–service-
n/a
affecting
Probable Cause
If secondary storage is not reachable, the
NE raises a noSecondaryDatabase alarm.
minor
non–service-
n/a
affecting
Probable Cause
Raised when copying OSL to secondary
storage (USB flash drive).
Location
Description
NEND
ZTP Boot in progress.
Suggested Corrective Action
No action is required.
Note: This alarms clears when auto-upgrade completes or
aborts and ZTP Boot closes.
Location
Description
NEND
Secondary storage is not present or
available.
Suggested Corrective Action
Disable secondary database if USB flash drive is not used.
Note: Clears when a USB flash drive is present in the USB
slot.
NEND
No secondary database
Suggested Corrective Action
1. Connect secondary storage.
2. After NE can successfully back up database in
secondary storage, this alarm clears.
NEND
Software synchronization is in progress.
Suggested Corrective Action
Clears when copying is complete.
Fujitsu and Fujitsu Customer Use Only