System Maintenance
Trouble Clearing
Entity Type
1GEX SFP
100ME SFP
100ME SFP
1GEBT SFP
1GEBT SFP

equipmentInterConnectFailure

Entity Type
·
Release 19.1.1
Issue 1.1, May 2021
Service
Severity
Direction
Affected
critical
service-
n/a
affecting
Probable Cause
A 1GEX SFP module has failed.
minor
non–service-
n/a
affecting
Probable Cause
A 100ME SFP module has failed.
critical
service-
n/a
affecting
Probable Cause
A 100ME SFP module has failed.
minor
non–service-
n/a
affecting
Probable Cause
A 1GEBT SFP module has failed.
critical
service-
n/a
affecting
Probable Cause
A 1GEBT SFP module has failed.
Service
Severity
Direction
Affected
major
non–service-
n/a
affecting
Probable Cause
A failure has occurred in the interblade
communication links that connect the
blades.
Location
Description
NEND
Equipment Fault: TYPE=<unit type>
Suggested Corrective Action
Replace the failed SFP module as soon as possible.
NEND
Equipment Fault: TYPE=<unit type>
Suggested Corrective Action
Replace the failed SFP module as soon as possible.
NEND
Equipment Fault: TYPE=<unit type>
Suggested Corrective Action
Replace the failed SFP module as soon as possible.
NEND
Equipment Fault: TYPE=<unit type>
Suggested Corrective Action
Replace the failed SFP module as soon as possible.
NEND
Equipment Fault: TYPE=<unit type>
Suggested Corrective Action
Replace the failed SFP module as soon as possible.
Location
Description
NEND
Interblade communication Link Failure:
TYPE = <unit type>
Suggested Corrective Action
1. Check for loose connectors on each interblade
communication link.
2. Check for and replace any damaged interblade
communication cables.