System Maintenance
Trouble Clearing
Entity Type
oms
eth
eth
·
Release 19.1.1
Issue 1.1, May 2021
Service
Severity
Direction
Affected
critical
service-
receive
affecting
Probable Cause
A loss of incoming signal exists on the
specified OMS entity.
major
non–service-
receive
affecting
Probable Cause
A loss of incoming signal exists on the
specified Ethernet entity.
major
service-
receive
affecting
Probable Cause
A loss of incoming signal exists on the
specified Ethernet entity.
Location
Description
NEND
Loss of Signal
Suggested Corrective Action
1. Check the local and upstream SFP modules for removal
or failure.
2. Check the fiber link and perform trouble-clearing
procedures, as necessary.
3. Verify the local receive and remote transmit optical
levels.
4. Verify good optical connections to the local and far-end
SFP modules.
NEND
Loss of Signal
Suggested Corrective Action
1. Check the local and upstream SFP modules for removal
or failure.
2. Check the fiber link and perform trouble-clearing
procedures, as necessary.
3. Verify the local receive and remote transmit optical
levels.
4. Verify good optical connections to the local and far-end
SFP modules.
NEND
Loss of Signal
Suggested Corrective Action
1. Check the local and upstream SFP modules for removal
or failure.
2. Check the fiber link and perform trouble-clearing
procedures, as necessary.
3. Verify the local receive and remote transmit optical
levels.
4. Verify good optical connections to the local and far-end
SFP modules.